Complete Ventilation Solutions Across South Africa
Request a quotation today. Call us on +27 (0)11 433 0116 or email info@ventinstallation.co.za
Kitchen Extraction System Installation (Industrial and Commercial)
We install complete kitchen extraction systems that are tailored to the layout and operational requirements of each space.
Site Assessment
Every project starts with a site assessment. We review the kitchen layout, cooking equipment, and the level of heat and smoke generated. This allows us to determine the correct system design, ducting routes, and extraction requirements.
Fan Installation
Extraction fans are installed externally, either on the roof or outside wall, depending on the building structure. These are fitted securely, aligned for correct airflow direction, and installed with vibration control to reduce noise.
Testing and Commissioning
Once installed, the system is tested to confirm airflow, performance, and overall operation before completion.
Hood and Ducting Installation
The extraction hood is installed above cooking equipment at the appropriate height to ensure effective capture of heat, smoke, and grease. Ducting is then installed using galvanised steel or stainless steel, with careful attention to keeping runs as straight as possible to maintain strong airflow. All joints are sealed properly to prevent leaks, and access points are included for future cleaning.
Electrical and System Setup
All electrical connections are completed in line with required standards, including isolators and speed controls where necessary.



Fan Replacement
Over time, extraction fans can lose performance due to wear, damage, or motor failure. Reduced airflow or increased noise are common indicators that a replacement is required.
Professional Fan Replacement & Airflow Restoration
We safely isolate the system, remove the existing fan, and inspect the surrounding ducting and electrical connections. A replacement fan is then installed based on the correct airflow requirements, ensuring the system returns to proper operating performance.
Once installed, the system is tested to confirm that airflow and operation meet the required standard.




Cleaning (Fire Risk Prevention)
Regular cleaning plays a critical role in maintaining a safe ventilation system. Grease buildup within hoods, ducting, and fans can increase the risk of fire and reduce system efficiency.
Extraction System Cleaning & Degreasing
We clean all key components of the system, including filters, internal ducting, and fan assemblies. Filters are removed and cleaned using degreasers, while ducting is cleared of accumulated grease using appropriate cleaning methods.
Cleaning schedules can be structured based on usage, with higher-demand kitchens requiring more frequent servicing.


Maintenance
Routine maintenance helps keep your ventilation system running efficiently and safely over time.
During a typical check, we inspect the fan motor and bearings, check the ducting for any leaks or damage, and make sure filters are clean and not restricting airflow. We also tighten any loose fittings and review all electrical connections to ensure everything is working as it should.
Monthly
A basic inspection to ensure the system is running correctly and there are no early signs of wear or issues.
Quarterly
A more thorough clean along with a full system check to maintain airflow and prevent buildup.
Annually
A complete service and performance test to ensure the system is operating at the required standard.